  rev.08.04.11_77 IMP series 1 of 9 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 embedded power for business-critical continuity electrical specifications fo nt : minion bold for mp mi nion italic for i ; size for each is the same cr e at ed on mac co lor: "i" 100% blue , 50% magenta 0% yellow , 0% black "mp" - 100% black ? input input ra nge: 85 - 264 vac 120 - 350 vdc (limited to 300 vdc in medical applications) frequency: 47 - 440 hz inrush current: 40 a peak max. (soft start) efficiency: up to 85% @ full case load power factor: 0.99 typ. meets en61000-3-2 (n/a @ 440 hz) turn-on time: ac on 2.0 sec typ., inhibit/enable 150 ms typical programmable delay; 50 ms internal turn-on delay (dual output only) emi filter: cispr 22/en55022 level b** leakage current: 300 a max. @ 240 vac; 47 - 63 hz radiated emi: cispr 22/en55022 level b** holdover storage: 20 ms minimum (independent of input vac) additional 34ms holdover storage with optional hup module (semi f47 compatible). for IMP4 15 ms (low-line), 10 ms (high-line) ac ok: > 5 ms early warning min. before outputs lose regulation full cycle ride thru (50 hz) (n/a on IMP4 > 750 w @ 90 vac) harmonic distortion: meets en61000-3-2 isolation: meets en60950 and en60601 global inhibit/enable: ttl, logic 1 and logic 0; configurable input fuse (internal): IMP4: 16 a; IMP8: 20 a; IMP1: 25 a (both lines fused) warranty: 2 years intelligent mp series up to 1500 watts special features ? full medical en60601 approval ? intelligent i 2 c control ? voltage adjustment on all outputs (manual or i 2 c) ? configurable input and output (case and module) ok signals and indicators ? configurable inhibit/enable ? configurable output up/down sequencing ? configurable current limit (foldback or constant current) ? high power density (8.8 w/cu-in) ? intelligent fan (speed control/fault status) ? downloadable gui from website ? customer provided air option ? up controlled pfc input with active inrush protection ? i 2 c monitor of voltage, current, and temp ? programmable voltage, current limit, inhibit/enable through i 2 c ? optional extended hold-up module (semi f47 compliance) ? increased power density to 50% over standard mp ? external switching frequency sync input ? optional conformal coating ? industrial temp range (-40 oc to 70 oc) ? no preload required ? industrial shock/vibration (> 50gs) total power: up to 1500 watts input voltage: 85 - 264 vac 120-300 vdc # of outputs: up to 21 safety ? ul ul60950/ul2601** ? csa csa22.2 no. 234 level 5 ? vde en60950/en60601-1** ? babt compliance to en60950/en60601 bs7002 ? cb certificate and report ? ce mark to lvd
rev.08.04.11_77 IMP series 2 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 output module line-up operating temperature: -40 to 70 c ambient. derate each output 2.5% per degree from 50 c to 70 c. ( -20 c start up) storage temperature: -40 c to 85 c electromagnetic susceptibility: designed to meet en61000-4; -2, -3, -4, -5, -6, -8, -11 level 3 humidity: operating; non-condensing 10% to 95% rh vibration: iec68-2-6 to the levels of iec721-3-2 mtbf demonstrated > 550,000 hours at full load, 220 vac and 25 c ambient conditions environmental specifications output adjustment range:* 10% minimum all outputs (manual) (full module adjustment range using i 2 c) factory set point accuracy: 1% i 2 c output program accuracy: 5% margining: 4 - 6% nominal analog (single output module only) overall regulation: 0.4% or 20 mv max. (1500w modules 1% max.) (36 w modules 4% maximum) ripple: rms: 0.1% or 10mv, whichever is greater pk-pk: 1.0% or 50mv, whichever is greater bandwidth limited to 20 mhz dynamic response: < 2% or 100 mv, with 25% load step recovery time: to within 1% in < 300 sec overcurrent protection:** configurable through i 2 c (calibration required). single output module and main output of the dual output module 105 - 120% of rated output current. aux output of dual output module 105 - 140% of rated output current short-circuit protection: protected for continuous short-circuit recovery is automatic upon removal of short overvoltage protection:* configurable through i 2 c single output module: 2 - 5.5 v 122 - 134% ; 6 - 60 v 110 - 120% dual output module: 2 - 6 v 122 - 134% ; 8 - 28 v 110 - 120% triple output module: 110 - 120% of highest voltage rating output continued reverse voltage protection: 100% of rated output current thermal protection:* (otp and otw) configurable through i 2 c all outputs disabled when internal temp exceeds safe operating range. > 5 ms warning (ac ok signal) before shutdown remote sense: up to 0.5 v total drop (not available on triple output module) single wire parallel: current share to within 2% of total rated current dc ok:* 5% of nominal. configurable through i 2 c minimum load: not required housekeeping standby: 5 vdc @ 1.0 a max. present whenever ac input is applied (optional 2.0 a available) module inhibit:* configured and controlled through i 2 c switching frequency: 250k hz a ccepts external sync signal output/output isolation: >1 megohm, 500 v external sync: ttl clock input signal used to adjust switching frequency. frequency 500 khz 20%; duty cycle 40 - 55% * can be controlled via i 2 c ** controlled via i 2 c but requires load calibration module code 1 2 3 5 4 module type single single single single dual triple max output power 210 w 360 w 750 w 1500 w 144 w 36 w max output current 35 a 60 a 150 a 140 a 10 a 2 a output voltages available* 2-60 v 2-60 v 2-60 v 6-60 v 8 - 15*, 24 - 28; 8 - 15*, 8 - 15*; 8 - 15*, 2 - 6; 2 - 6, 2 - 6; 24 - 28, 24 - 28; 24 - 28, 2 - 6 8-15, 8-15, 2-6; 8-15, 8-15, 8-15; 8-15, 8-15, 18-28; 8-15, 18-28, 2-6 standard voltage increments 25 25 25 18 16 18 remote sense yes yes yes yes yes yes no remote margin yes yes yes yes no no no v-program - i 2 c control yes yes yes yes yes yes no active current share yes yes yes yes yes no no module inhibit - i 2 c control yes yes yes yes yes yes yes module inhibit - analog yes yes yes yes yes no no overvoltage/overcurrent protection yes yes yes yes yes yes yes minimum load required no no no no no no no slots occupied in any ivs case 1 2 3 4 1 1 * note: contact factory for extended range down to 6 v
rev.08.04.11_77 IMP series 3 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 7 6 5 4 3 2 1 IMP4 available slots IMP8 available slots slot 1 slot 2 slot 3 slot 4 slot 5 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 1 slot 2 slot 3 slot 4 slot 6 slot 7 slot 5 IMP1 available slots parallel codes 0 = no parallel 1 = 1 & 2 2 = 2 & 3 3 = 3 & 4 4 = 4 & 5 5 = 3 & 4 & 5 6 = 5 & 6 7 = 4 & 5 & 6 8 = 6 & 7 9 = 3 & 4, 6 & 7 a = 1 & 2, 3 & 4, 5 & 6 c = 2 & 3, 4 & 5 e = 3 & 4, 5 & 6 f = 2 & 3, 4 & 5, 6 & 7 output module voltage/current ordering note: 1. the cases and modules of both mp and IMP series can be interchanged to allow more flexibility. if intelligent modules are used with non-intelligent cases, a numeric code 4 is placed at the end of the module code (ex. 4ll0 becomes 4ll4). 2. usb to i 2 c module order code 73-769-001 IMP1* - 3l0 - 2e2 - 1q1 - 4ll0 - 00 - a - ### case size (mm) 4 = 2.5 x 5 x 10; 750 w-1100 w, 5 slots (63.5 x 127 x 254) 8 = 2.5 x 7 x 10; 1000 w-1200 w, 6 slots (63.5 x 177.8 x 254) 1 = 2.5 x 8 x 11; 1200 w-1500 w, 7 slots (63.5 x 203.2 x 279.4) *note: add e after IMP4 to denote iec input option. e.g. IMP4e (not available on IMP8 or IMP1) module codes module/voltage/option codes module codes: (none) = 36 w triple o/p (1 slot) 1 = 210 w single o/p (1 slot) 2 = 360 w single o/p (2 slot) 3 = 750 w single o/p (3 slot) 4 = 144 w dual o/p (1 slot) 5 = 1500 w single o/p (4 slot) 6 - 9 = future case option codes first digit 0 - 9 = parallel code (see parallel codes table above) second digit 0 = no options 1 = reverse air 3 = global enable 4 = fan idle with inhibit 5 = opt 1 + opt 3 6 = opt 1 + opt 4 7 = opt 3 + opt 4 8 = opt 1 +3 +4 9 = can bus/rs485 73-544-002 c = opt 3 + opt 9 software code voltage codes: see output module voltage/current table above option codes: 0 = standard 1 = module enable 2 = constant current 3 = 1 & 2 combined 4 = set for use in standard (non-intelligent case) 5 = shutdown mode for 1500w 6 = 1 & 5 combined 7 - 9 = future module/voltage/option codes first - module code second - voltage code third - option code case option codes software code used for configura - tion change. a is standard case size factory assembled for hardware of firmware mods. hardware code ordering information voltage voltage code single output module code dual output*** triple output i 2 c adjustment ranges**** 1 2 3 5 + 4 4 - - - 2 v a 35 a 60 a 150 a 10 a 10 a 2 a 1.8 - 2.2 2.2 v b 35 a 60 a 150 a 10 a 10 a 2 a 2.0 - 2.4 3 v c 35 a 60 a 150 a 10 a 10 a 2 a 2.7 - 3.3 3.3 v d 35 a 60 a 150 a 10 a 10 a 2 a 3.0 - 3.6 5 v e 35 a 60 a 150 a 10 a 10 a 2 a 4.5 - 5.5 5.2 v f 35 a 60 a 144 a 10 a 10 a 2 a 4.7 - 5.7 5.5 v g 34 a 58 a 136 a 10 a 10 a 2 a 5.0 - 6.1 6.0 v h 23 a 42 a 97.5 a 140 a 10 a* 10 a* 2 a 5.4 - 6.6 8.0 v i 20 a 36 a 84.4 a 140 a 10 a 4 a 1 a 1 a 1 a 7.2 - 8.8 10 v j 18 a 32 a 75 a 140 a 10 a 4 a 1 a 1 a 1 a 9.0 - 11.0 11 v k 17 a 31 a 68 a 136.3 a 10 a 4 a 1 a 1 a 1 a 9.9 - 12.1 12 v l 17 a 30 a 62.5 a 125 a 10 a 4 a 1 a 1 a 1 a 10.8 - 13.2 14 v m 14 a 21 a 53.5 a 107 a 9 a 4 a 1 a 1 a 1 a 12.6 - 15.4 15 v n 14 a 20 a 50 a 100 a 8 a 4 a 1 a 1 a 1 a 13.5 - 16.5 18 v o 11 a 19 a 41.6 a 83.3 a 0.5 a 0.5 a 16.2 - 19.8 20 v p 10.5 a 18 a 37.5 a 75 a 0.5 a 0.5 a 18.0 - 22.0 24 v q 8.5 a 15 a 30 a 62.5 a 4 a 2 a 0.5 a 0.5 a 21.6 - 26.4 28 v r 6.7 a 11 a 26.8 a 53.5 a 3 a 2 a 0.5 a 0.5 a 25.2 - 30.8 30 v s 6.5 a 11 a 25 a 50 a 27.0 - 33.0 33 v t 6.2 a 10.9 a 22.7 a 35.8 a 29.7 - 36.3 36 v u 5.8 a 10 a 20.8 a 35.8 a 32.4 - 39.6 42 v v 4.2 a 7.5 a 16 a 35.7 a 37.8 - 46.2 48 v w 4.0 a 7.5 a 15.6 a 31.2 a 43.2 - 52.8 54 v x 3.7 a 6.0 a 13.9 a 27.7 a 48.6 - 59.4 60 v y 3.5 a 6.0 a 12.5 a 25 a 54.0 - 66.0 non-std** z special voltage - consult factory for specifications *note: contact factory for extended range down to 6 v. **increments of current not shown can be achieved by paralleling modules (add currents of each module selected). ***total output power on dual module must not exceed 144 w. **** for single output modules only. + applicable for IMP1 only.
rev.08.04.11_77 IMP series 4 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 input 85-264 vac 180-264 vac IMP 8 = 2.5 x 7 x 10 6 available slots 1000 w max. 1200 w max. (63.5 x 177.8 x 254mm) IMP 1 = 2.5 x 8 x 11 7 available slots 1200 w max. 1500 w max. (63.5 x 203.2 x 279.4mm) s l o t 7 s l o t 5 s l o t 6 s l o t 4 s l o t 3 s l o t 2 s l o t 1 -a- s l o t s l o t s l o t s l o t s l o t 5 4 32 1 IMP4 (ac input on opposite side) IMP8 and IMP1 IMP1 only single ac input figure 1. ac inpu t 1 2 3 ~ n 6 1 10 5 fi gu re 2. connector j 1 ac input pin no. function 1 ac neutral 2 ac line (hot) 3 chassis (earth) ground pfc input connector (control and signals) pin no. function 1 input ac ok - emitter 2 input ac ok - collector 3 global dc ok - emitter 4 global dc ok - collector 5 external sync 6 global inhibit/optional enable logic 0 7 global inhibit/optional enable logic 1 8 global inhibit/optional enable return 9 +5 vsb housekeeping 10 +5 vsb housekeeping return i 2 c bus output connector pin no. function 1 no connection 2 no connection 3 no connection 4 serial clock signal (scl) 5 serial data signal (sda) 6 address bit 0 (a0) 7 address bit 1 (a1) 8 address bit 2 (a2) 9 secondary return (gnd) 10 5 vcc external bus (5 vcc. bus) mates with molex 90142-0010 housing 90119-2110 pin connector kit part no.: 70-841-004 mates with landwin 2050s1000 housing 2053t011v pin or jst phdr-10vs housing jst sphd-002t-p0.5 (28-24) jst sphd-001t-p0.5 (26-22) connector kit part no.: 70-841-023 figure 1. ac input figure 2. connector j1 figure 3. connector j2 figure 1. ac inpu t 1 2 3 ~ n 6 1 10 5 fi gu re 2. connector j 1 input 90-264 vac 180-264 vac IMP 4 = 2.5 x 5 x 10 5 available slots 750 w max. 1100 w max. (63.5 x 127 x 254) 210 w 360 w 750 w 144 w pin connectors triple dual 6 1 10 5 figure 3. c onne ctor j 2 12 7 3 figure 4. connector cn50x 36 w 1500 w
rev.08.04.11_77 IMP series 5 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 dc-dc converter output modules control signal information, j1 control connector pin no. function 1 + remote sense single or dual o/p main 2 remote margin / v. program single o/p 3 margin high single o/p 4 - remote sense / margin low single or dual o/p main 5 spare 6 module, isolated inhibit single or dual o/p 7 module inhibit return single or dual o/p 8 current share (swp) single or dual o/p main 9 + remote sense v2 dual o/p, single is spare 10 - remote sense v2 dual o/p, single is spare *note: all IMP modules have a green dcok led. (except for 36 w module) .63? (16.0) .32? (8.1) 1.38? (35.2) (2x) .44? (11.4) .48? (12.1) (2x) .33? (8.5) v adj v- v+ m 4 x 8 screws with conical washer dc output connector pin 1 .44" (11.4) .32" (8.1) 1.38" (35.1) .48" (12.1) .44? (11.2) 2x v+ m4x8 screws with conical washer dc output connector pin 1 v- v adj pin 1 v2 adj .32 (8.1) .42 (10.7) v1 + v1 - v2 + m3x8 scre ws with spring w as her (4x) .46 (11.7) (4x) .30 (7.5) (3x) v1 adj 1.17 (29.7) v2 - single 210 watt dual 144 watt single 360 watt single 750 watt IMP modules triple 36 watt v1 adj v2 adj v3 adj v1+ v3+ v1- v2+ v2- v3- .32" (8.1) .44" (11.0) 1.24"(11.0) (2x) .61"(15.6) (2x) .59" (15.0) .63" (16.0) v+ v- m4x8 screws (4x) v adj pin 1 dc output connector      ~ n mates with molex 90142-0010 housing 90119-2110 pin figure 4. connector j1 v1 + v1 - v2 - v3 - v3 + v2 + mates with molex 09-91-0600 housing 26-60-5060 pin single 1500 watt v- v+ 59.3 0.2 (2x) 15.0 0.8 (2x) 16.0 0.2 (2x) 16.0 0.2 (3x) 31.6 0.8 11.3 0.8 8.1 0.8 dc output co nne ct or pin 1 m4x8 scre ws w/ co ni ca l wa sh er (6x) fo r fa ct or y- us e only va dj
rev.08.04.11_77 IMP series 6 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 notes 1. input: barrier type. three no. 6-32 b.h. screws (0.375 centers). max torque: 6 in-lbs. (0.67 n-m). (optional iec input connector) 2. control connectors: (j1) 10 position housing, gold plated contacts. mates with molex 90142-0010 housing with 90119-2110 crIMP contacts (molex c - grid iii series). connector kit includes mating connector and 10 pins, astec part #70-841-004. (j2) 10 position housing (landwin 2051p1000t). mates with housing 2050s1000 (landwin) with 2053t011p (landwin) pins or jst phdr-iovs housing and jst sphd-002t-po.5 pins. 3. chassis material: aluminum with chemical film coating (conductive). 4. all dimensions are in millimeters and inches, and are typical. 5. customer mounting -3 sides m4, bottom also includes 8-32 mounting holes. max. penetration is 0.150 (3.8 mm). max. torque: 5 in-lbs. (0.57 n-m). 6. output module connections: all single o/p modules are m4 x 8mm screws. max. torque: 10 in-lbs. (1.13 n-m). dual o/p module is m3 x 8mm screws. max. torque: 5 in-lbs. (0.57 n-m). IMP series i mp4 (750/1100 watts max) 5-inch case size: IMP4: 2.5 x 5 x 10 (63.5mm x 127mm x 254mm) weight: i mp4 case: 3 lbs. ? 360 w single 1.0 lb. ? 750 w single: 1.6 lbs. 144 w dual: 0.6 lb.
rev.08.04.11_77 IMP series 7 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 i mp series i mp8 (1000/1200 watts max) 7-inch case size: IMP8: 2.5 x 7 x 10 (63.5mm x 177.8mm x 254mm) weight: i mp8 case: 4.1 lbs. ? 210 w single: 0.6 lb. ? 360 w single: 1.0 lb. ? 750 w single: 1.6 lbs. 144 w dual: 0.6 lb. notes 1. input: barrier type. three no. 6-32 b.h. screws (0.375 centers). max torque: 6 in-lbs. (0.67 n-m). 2. control connectors: (j1) 10 position housing, gold plated contacts. mates with molex 90142-0010 housing with 90119-2110 crIMP contacts (molex c - grid iii series) connector kit includes mating connector and 10 pins, astec part #70-841-004. (j2) 10 position housing (landwin 2051p1000t). mates with housing 2050s1000 (landwin) with 2053t011p (landwin) pins or jst phdr-iovs housing and jst sphd-002t-po.5 pins. 3. chassis material: aluminum with chemical film coating (conductive). 4. all dimensions are in millimeters and inches, and are typical. 5. customer mounting -3 sides m4, bottom also includes 8-32 mounting holes. max. penetration is 0.150 (3.8 mm). max. torque: 5 in-lbs. (0.57 n-m). 6. output module connections: all single o/p modules are m4 x 8mm screws. max. torque: 10 in-lbs. (1.13 n-m). dual o/p module is m3 x 8mm screws. max. torque: 5 in-lbs. (0.57 n-m). x y xx x y y y 171.45 171.45 177.8 19.05 m4 mounting holes (4x) marked as x #8-32 mounting holes (4x) marked as y m4 mounting holes (4x) identical both sides 38.10 normal air flow reverse air flow
rev.08.04.11_77 IMP series 8 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 x y xx x y y y 171.45 171.45 177.8 19.05 m4 mounting holes (4x) marked as x #8-32 mounting holes (4x) marked as y m4 mounting holes (4x) identical both sides 38.10 normal air flow reverse air flow 8-inch case size: IMP1: 2.5 x 8 x 11 (63.5mm x 203.2mm x 279.4mm) weight: i mp1 case: 5.0 lb. ? 210 w single: 0.6 lb. ? 360 w single: 1.0 lb. ? 750 w single: 1.6 lb. ? 144 w dual: 0.6 lb. notes 1. input: barrier type. three no. 6-32 b.h. screws (0.375 centers). max torque: 6 in-lbs (0.67 n-m). 2. control connectors: (j1) 10 position housing, gold plated contacts. mates with molex 90142-0010 housing with 90119-2110 crIMP contacts (molex c - grid iii series). connector kit includes mating connector and 10 pins, astec part #70-841-004. (j2) 10 position housing (landwin 2051p1000t). mates with housing 2050s1000 (landwin) with 2053t011p (landwin) pins or jst phdr-iovs housing and jst sphd-002t-po.5 pins. 3. chassis material: aluminum with chemical film coating (conductive). 4. all dimensions are in millimeters and inches, and are typical. 5. customer mounting -3 sides m4, bottom also includes 8-32 mounting holes. max. penetration is 0.150 (3.8 mm). max. torque: 5 in-lbs. (0.57 n-m). 6. output module connections: all single o/p modules are m4 x 8mm screws. max. torque: 10 in-lbs. (1.13 n-m). dual o/p module is m3 x 8mm screws. max. torque: 5 in-lbs. (0.57 n-m). IMP series i mp1 (1200/1500 watts max)
rev.08.04.11_77 IMP series 9 of 9 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 americas 5810 van allen way carlsbad, ca 92008 usa telephone: +1 760 930 4600 facsimile: +1 760 930 0698 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom telephone: +44 (0) 1384 842 211 facsimile: +44 (0) 1384 843 355 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong telephone: +852 2176 3333 facsimile: +852 2176 3888 for global contact, visit: www.emerson.com/embeddedpower techsupport.embeddedpower @emerson.com while every precaution has been taken to ensure accuracy and completeness in this literature, emerson network power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. emerson network power and the emerson network power logo are trademarks and service marks of emerson electric co. ?2011 emerson electric co. emersonnetworkpower.com embedded computing embedded power monitoring outside plant power switching & controls precision cooling racks & integrated cabinets services surge protection emerson network power. the global leader in enabling business-critical continuity. ac power connectivity dc power optional canbus or rs485 interface the rs485/can-to-i 2 c uses 2 input protocols and 1 output protocol. the input protocols used are rs485 using modbus (command index: 0x01), and can using modified modus (command index: 0x02). the output protocol use is: i 2 c with smbus support (command index: 0x80). ma st er /c lie nt de vi ce (s ) ad ap te r ou tp ut pr ot oc ol s sl ave/ se rv er de vi ce (s ) ad apte r pr otocol in pu t pr otocol s ad ap t er c om ma n d rs 485 us in g mo dbus a d a p te r co nt ro l s can us in g mo di fi ed mo db us i 2 c wi th sm bu s su ppor t rs485/can - to - i2c for detailed info, download the software requirements specification (srs) from www.powerconversion.com/IMP IMP can rs485